(1) performance indicators, such as:


Operating wavelength: According to the law of blackbody radiation, in the short wavelength band of the spectrum by the temperature-induced changes in radiant energy will exceed the change in radiant energy caused by the emissivity error, therefore, the temperature measurement should try to use the short-wave is better, but must be combined with the object to be detected to consider the emissivity of the factors:


The emissivity of the target material and surface properties determine the corresponding wavelength of the spectra of the pyrometer, for high reflectivity alloy materials, there are low or changing emissivity. In the high temperature zone, the measurement of metal materials jia wavelength is near infrared, can choose {{0}}.8 ~ 1.0 μm. other temperature zones can be selected 1.6, 2.2 and 3.9 μm. due to some materials at a certain wavelength is transparent, infrared energy will penetrate these materials, for this material should choose a special wavelength, such as measuring the internal temperature of the glass wavelengths 1.0, 2.2 and 3.9 μm (the glass to be tested) To be very thick, otherwise it will pass through); measure the surface temperature of the glass selection of 5.0 μm; measurement of low-temperature zone selection of 8 ~ 14 μm is appropriate, as well as the measurement of polyethylene plastic film selection of 3.43 μm, polyester class selection of 4.3 or 7.9 μm, the thickness of more than 0.4mm selection of 8 ~ 14 μm, such as measurement of the flame CO with a narrow band of 4.64 μm, measurement of the flame of 4.47 μm with the NO2, and so on.



(2) environmental and working conditions
Protection of accessories: the environmental conditions in which the pyrometer has a great impact on the measurement results, such as not properly resolved, will affect the temperature measurement accuracy or even cause damage. When the ambient temperature is high, the presence of dust, smoke and steam conditions, you can choose to use the manufacturer to provide a protective cover, water cooling, air cooling system, air blowers and other accessories. These accessories can effectively solve the environmental impact and protect the pyrometer to achieve accurate temperature measurement. When in the noise, electromagnetic fields, vibration or difficult to access the environmental conditions, or other harsh conditions, smoke, dust or other particles to reduce the measurement of energy signal, more appropriate is to choose the fiber optic dual-color pyrometer.


(3) other options, such as simple operation, ease of use, maintenance and calibration performance and price.

 

2 infrared thermometer

Sende bookingforespørsel